Journal article by E. Jasiūnienė, L. Mažeika and R. Šliteris of Kaunas University of Technology, from Ultragarsas Nr.1(26), 1996. It covers the principles of reflection tomography, a filtered backprojection algorithm over circular arcs under the Born approximation, and deconvolution. It compares simulated point-reflector images at 2.5 MHz with experimental reconstructions of copper wires, a chip and sheet reflectors. It is filed in the Techniscan-related folder, apparently kept by Phil as a useful reference.
AI-written summary; may contain errors.
Extracted text (machine-read; may contain errors)
ISSN 1392-2114 ULTRAGARSAS. Nr.1(26). 1996.
7 Experimental results in ultrasound refl ection tomography for nondestructive
testing
E.Jasiūnienė, L.Mažeika, R.Šliteris
Prof. K.Baršauskas Ultrasound Research Center
Kaunas University of Technology
Introduction
Tomography is the cross-sectional imaging of an
object. Data are collected illuminating object from many different directions in transmission or reflection mode. Computed tomography imaging is the reconstruction of a cross-section of a test object from its projections [ 4, 7]. This cross-section of the object can be at any location and
orientation. Such imaging can be done using different types of energy: ultrasound, electrons, alpha particles, lasers and radar [ 3, 4, 7].
The tomogaphic imaging is more highly detailed then
other forms of imaging, because this method reconstructs single selected plane of three dimensional object. In addition, in computed tomography it is possible to use image enhancement algorithms [ 3]. In conventional methods of imaging a three-dimensional object is displayed in two dimensions, and therefore superposition of features occurs. Then reflective nonhomogenities from outside of plane of interest are superimposed one on another. This makes detection and characterization of discontinuities more difficult [ 3, 7].
Ultrasonic energy gives the vi ew of the cross-section,
not available with other types of energy, because it measures the elastic properties of the material. Mapping of the elastic discontinuities gives different pattern than the mapping of absorption and scattering coefficients. Ultrasonic measurement provides data most closely related to determination of the material under the test properties (nonhomogenities, their position, shape and size), what is for us of main interest [ 1, 2, 7]. Ultrasound tomography can be divided into transmission and reflection tomography. The use of ultrasound tomography for nondestructive testing is different for transmission and reflection modes. Usually the transmission ultrasonic tomography is used for determining variations in a material density, a composition and a residual stress. The reflective ultrasonic tomography usually is used to locate and size discontinuities, erosion, corrosion of metals and to characterize voids and inclusions [ 3, 6].
In ultrasonic tomography the wavelength is
comparable to the size of an object nonhomogenities.
Therefore diffraction can occur, and several methods have been introduced for reconstruction of the image, taking into account diffraction effects [ 4, 6- 10]. The goal of our work was to investigate, what results it is possible to obtain using the filtered backpropagation algorithm in an ultrasonic non-destructive testing, neglecting the diffraction effects. Also the effect of the deconvolution
was investigated.
Basic Principals of Reflection Tomography
The basic aim of the ultrasonic reflection tomography
is to construct a quantitative cross-sectional image displaying a specific ultrasonic parameter of the material
under a test from the reflection data. The size and location of the detected discontinuity or material interface can be
estimated by the amplitude and the time of flight of the reflected signal [ 2, 3].
One nice aspect of the reflection tomography in
comparison with transmission tomography is that it is not necessary to encircle the object with transmitters and receivers for collection of pr ojections data. Transmission
and reception of signals are performed by the same transducer [ 2, 4]. However, because most of an ultrasonic
energy is scattered in the forw ard direction, the transducer
must have high sensitivity in order to measure backscattered signals at high signal-to-noise ratios [ 3, 5].
Reflection tomography measures line integrals of the
object reflectivity function [ 2, 4]. An object is illuminated by a very wide fan-shaped beam. A broad band transducer is used for transmitting and r eceiving signals [ 3, 5]. The
transducer is rotated around the object at a radius R, and its
position is indicated by (R,
θ) (Fig.1). The transducer
transmits and receives pulse signals, reflected from
nonhomogenities. The received signal at the time instant t
represents the total of all reflections at the distance d from
the transducer:
dtc=2, ( 1 )
where c is the ultrasound velocity in the object.
Rd
ρ(ρ,ϕ)(R,θ)
θϕ
Fig.1 . Transducer position is indicated by (R, θ) and the position of
the nonhomogenity by ( ρ,ϕ)
ISSN 1392-2114 ULTRAGARSAS. Nr.1(26). 1996.
8 In the far field of the tr ansducer distances from the
center and the sides of the tran sducer are almost the same,
so we can assume that we are using a point type transducer
[ 4]. The points at the same di stance from the transducer are
located on the arc, thus refl ection tomography measures
line integrals over circular ar cs. From the received signals
the ultrasonic image of nonhomogenities (objects reflectivity function) can be reconstructed [ 2, 4]. Then, by moving the transducer over a sphere wrapped around an object it is possible to collect enough data to reconstruct the entire object.
The recovering of the image in ultrasound reflection
tomography is done in two steps [ 2, 4]:
1.Collection of the projection data; 2.Image reconstruction from projections.
Reconstruction Algorithm
The reflection tomography using point type
transducers gives line integrals of the object reflectivity function over circular arcs. One of the methods to reconstruct the reflectivity function of the object under the test is by carrying out a backprojection over circular arcs [ 4, 8, 9]. The derivation of the algorithm can be found in [ 4]. The reconstruction algorithm consists of the 3 steps:
1.The measured data ar e transformed into the
measures of line integrals over ci rcular arcs using formula:
()(){}
{}yd I F TFT y t
FT y tdrsc
in=⎡
⎣⎢
⎢⎤
⎦⎥
⎥()12, ( 2 )
where yr(d) is the estimate for the line integral of the
reflection data; ysc(t) is the scattered field measured by the
point type transducer; yin(t)is the transmitted signal; FT{ }
indicates a Fourier tran sform with respect to t; IFT{ }
represents the corresponding inverse Fourier transform, d
is the distance between the tran sducer and the circular arc.
1.The data are filtered with h(d)
() () ()yd y dh drf r=∗ ,( 3 )
where h(d) is the filter function, and * denotes
convolution.
Fourier transform of the filter function can be
expressed:
()Hc
c(),
,ωωπ ωω
ωω=<
≥⎧
⎨
⎩2
0, ( 4 )
where ωc is cutoff frequency.
2.Backprojection over circular arcs:
() ()[] fyrfdd ρϕπθρϕπ
θ ,, ,=∫1
202
, ( 5)
where the distance from th e transducer at (R, θ) to the
reconstruction point at ( ρ,ϕ) is given by () ( )dR Rθρϕ ρ ρ ϕ θ,, c o s=+ − −222 . ( 6)
For this type of the reconstruction algorithm it is
necessary that the Born approximation should hold. This means, that scattered fields must be small compared to incident fields. The absorption and the velocity variations of the field must be also sma ll. The scatterers in the object
must be isotropic, so that the field scattered by any point would be identical independently from the direction of the incident field.
Computer Simulation
In order to test the reconstruction algorithm and the
validity of the developed programs the computer simulations have been carried out.
We have assumed, that the dimensions of
nonhomogenities are smaller then the wavelength. It means that the nonhomeogenities are point type reflectors
and the reflection coefficient of the nonhomogenity is assumed to be equal to 1, that is, the whole incident field is reflected. The influence of the diffraction in the
reconstruction algorithm has been neglected. All calculations were made in two dimensional approach.
In order to test the possib ilities and the accuracy of the
reconstruction algorithm under given assumptions two models, consisting of point type reflectors, spaced at
different distances (Fig.2 and Fig.3), were used. We have assumed, that an ultrasound wave was propagating in water having the velocity of ultrasound c=1480m/s, the
frequency of the transducer was f=2.5MHz and the beam
divergence angle 45
°. We have assumed, that the
transducer transmits radio pulse with asymmetrical Gausian envelope, number of periods of which was 4.
Such a signal is very similar to the real signal, generated by the transducer.
5mm 2.5mm 1mm0.5mm
Fig.2. Reconstructed image of 5 point reflectors (simulated experiment)
ISSN 1392-2114 ULTRAGARSAS. Nr.1(26). 1996.
9 The wavelength of the transmitted wave
λ=c/f= 0.6mm .
The object was rotated from 0 to π. 256 projections
were calculated, each consis ting of 256 sampling points.
The reconstructed image consisted of 256 ×256 points.
The reconstructed images are presented in Fig.2 and 3.
From these pictures we can see theoretical possibilities an d limitations of the reconstruction algorithm under given assumptions. From the pictures it can be seen, that it is possible to resolve two refl ectors, even when distance
between them is only 0.5mm=0.83 λ.
In order to improve the spatial resolution of the images
deconvolution was performed. Deconvolution has to reduce the effect of the input signal waveform. Distortions in the images are only due to the fact , that performing
deconvolution, when spectrum of the input signal is 0, we have division by 0. It is possible to overcome this problem only by making some assumptions. Experimental Results
Experimental measurements were carried out to
confirm the simulation results. The block diagram of experimental set-up is presented in Fig.4. The transducer and the test object were located in the water tank. The frequency of the transducer was f=2.5MHz, and the beam
divergence angle 38
°. Experimental measurements where
made for two groups of test objects:
1.Three test objects were made from copper wires with
diameter 0.5mm, positioned in different way. Two of them were made the same, as for computer simulation. The third was micro chip. These test objects are difficult for imaging, because there are multiple reflections between
wires and therefore it is difficult to resolve wires, when they are near or behind one another.
2.Another two test objects were made from the sheet
of the copper: the corner and the wavy type reflectors. Objects of such complex struct ure are also very difficult to
image, because of the wave refraction phenomena.
The object was rotated from 0 to π and 105 projections
were taken, 256 samples in each. Data acquisition was done using visualization system ‘Ultralab-2’ [ 11], which was created in Ultrasound laboratory.
The images reconstructed from experimental data are
presented in Figures 5-9. If to compare these reconstructed images with images after com puter simulation, we can see,
that there are more noise around reflectors, but still for 5 point reflectors (Fig.5) it is possible to resolve two nonhomogenities, when distance between them is
0.5mm=0.83 λ, like in computer simulation. When there
are 4 reflectors at small distances near each other, we can only resolve two reflectors, when the distance between
them is 1mm=1.67 λ (Fig.6).
The pins of the chip (Fig.7) are well reconstructed
only from one side, mainly to the reason that we have taken projections only from half of the circle.
5mm
2.5mm
1mm5mm
2.5mm
1mm
0.5mm
Fig.3. Reconstructed image of 8 point reflectors (simulated experiment)
Computer
Pulse
GeneratorAmplifierA/D
Convertor
Stepping
motor
Transducer Test object Water Tank
Fig.4. Experimental setup
Fig.5. Reconstructed image of 5 point reflectors
Fig.6. Reconstructed image of 8 point reflectors
ISSN 1392-2114 ULTRAGARSAS. Nr.1(26). 1996.
10 In Fig.8 and Fig.9 the reconstructed images of objects,
having complex geometry, are presented. It can be seen, that the shape of th e corner and the wavy type reflectors
were well reconstructed.
The distortions in all reconstructed images are due to
multiple reflections, mechanical instability and also due to the fact that we don’t know exactly the waveform of the transmitted signal.
Conclusions
The main purpose of this work has been to carry out
an experimental verification of the filtered backpropagation algorithm in nondestructive testing. Our results show that, although the influence of the diffraction has been neglected, experimentally it has been established, that quite a good quality of reconstructed images can be obtained. It is possible to resolve nonhomogenities even
when distance between them is only 0.83 λ. It is also
possible to reconstruct images of objects having complex geometry.
It was proved that using deconvolution it is possible to
reduce the influence of the shape of the input signal and the reverberation noise.
Though there are limitations caused by diffraction
effects to the use of ultrasonic tomography for nondestructive testing, we ha ve shown, that good quality
images of the different objects could be obtained.
References
1. G.S.Kino . “Acoustic Imaging for Nonde structive Evaluation” Proc.
of the IEEE, vol.67, No.4, pp.510-525. 1979.
2. Неразрушающий контроль в 5 кн. Интроскопия и автоматизация
неразрушающего контроля : Практ . пособие / В.В.Сухоруков ,
Э.И.Вайнберг , Р.-Ю.Кажис , А.А.Абакумов ; под. ред.
В.В.Сухорукова .-М.: Высш . шк., 1993.
3. Nondestructive Testing Handbook, 2nd edition, vol.7. Ultrasonic
Testing/ Albert S.Birks, Robert E. Green, Paul McIntire.- USA: American Society for Nondestructive Testing, 1991.
4. P.A.C.Kak, M.Stanley. Principles of Computerized Tomographic
Imaging.-New York: IEEE Press, 1988.
5. Ультразвуковые преобразователи для неразрушающего
контроля ./ под. ред. И. Н. Ермолова .-М.: Машиностроение , 1986/
6. H.W.Jones. “Recent Activity in Ultrasonic Tomography”
Ultrasonics, vol.31, No.5, pp.353-360. 1993.
7. R.K.Mueller, M.Kaveh and G.Wade. “Reconstructive Tomography
and Applications to Ultrasonics” Proc. of the IEEE, vol.67, No.4, pp.567-587. 1979.
5mm
Fig.7. Reconstructed image of the chip
7mm5mm
Fig.8. Reconstructed image of the corner
10mm
Fig.9 . Reconstructed image of the wavy surface
ISSN 1392-2114 ULTRAGARSAS. Nr.1(26). 1996.
11 8. N.Sponheim and I.Johansen . ”Experimental Results in Ultrasonic
Tomography Using a Filtere d Backpropagation Algorithm”
Ultrasonic Imaging, vol.13, pp.56-70 1991.
9. N.Sponheim, L.-J.Gelius I.Joh ansen and J.J.Stamnes.
“Quantitative Results in Ultrasoni c Tomography of Large Objects
Using Line Sources and Curved Detector Arrays” IEEE Trans. on Ultrasonics, Ferroelectrics and Frequency Control, vol.38, No.4, pp.370-379. 1991.
10. L.Capineri, H.G.Tatersall, J.A.G.Temple and M.G.Silk. “Time of
Flight Diffraction Tomography fo r NDT Applications” Ultrasonics,
vol.30, No.5, pp.275-288. 1992.
11. V.Dumbrava, R.Kaþys, L.Maþeika, L.Svilainis. “Digital
Ultrasonic Imaging System: the So ftware Concept” Informatica,
vol.2, No.4, pp.478-597. 1991. E.Jasiūnienė, L.Mažeika, R.Šliteris
Ultragarsin ės atspinžio tomografijos taikymo neardan čioje kontroleje
eksperimentiniai rezultatai
Reziume
Šiame straipsnyje yra pateikti ek sperimentiniai rezultatai, gauti
taikant ultragarsin ę atspinžio tomografij ą neardančioje kontrol ėje. Vaizdų
atstatymui buvo naudojamas atvirkštinio projektavimo algoritmas. Kompiuteriniai skai čiavimai ir eksperimentiniai rezultatai parodo, kad net
prie priimt ų apribojm ų, galima atskirti du nevienalytiškumus, kai atstumas
tarp jų yra mažesnis už bangos ilg į. Taip pat galima atstatyti form ą
objektų, turinčių sudėtingą geometrij ą.