Draft section from Phil's transmission line manuscript, dated June 2014 with an October 2014 note calling it an unconvincing early version. It reviews why the bipolar-coordinate, electro-quasi-static and round-wire (Appendix D) theories may fail near DC, citing the radial Hall effect and a soft cutoff frequency ωc. It shows current density plots at low frequency and summarizes the E-field solutions and conclusions for an infinite, properly terminated line.
AI-written summary; may contain errors.
Extracted text (machine-read; may contain errors)
1
Section 6.5 (e) on Proximity Effect at low ω
PhL
6.21.14
This was installed around June 21, but will probably be rewritten once again soon.
// Yes, it was heavily rewritten. Below is a very early version of Section 6.5 (e) ! My bogus low loss
model with ωc is still alive at this point. I see that I was blaming a lot on the "capacitor problem" not
being valid at low ω, but I no longer think that is an issue. I really never liked this version of this section
6.5 (e) ! Very unconvincing. (10.8.14)
(e) The Proximity Effect At Low Frequencies
Validity of The Theory at Low Frequencies
The development presented above and leading to the current density plots like Fig 6.12 involves the
merging of three pieces of theory:
1. The bipolar-coordinates theory leading to n(θ) for the two cylinder geometry
2. Transmission line theory as presented in Chapters 4 and 5
3. Theory of the fields in a round wire as presented in Appendix D.
Item 1 involves the solution of the electrostatics problem of two parallel cylinders and thus does not
involve frequency ω. We therefore expect Item 1 to be just fine at "low frequency".
Item 2 involves the "electro-quasi-static" model for dealing with transmission lines. Contrary to what that
phrase intuitively suggests, we have shown that this model is valid for high frequencies and is known to
be invalid at low frequencies. For example, we had trouble in Fact 2 of (3.7.4) trying to prove that φ =
constant on a transmission line conductor at low frequencies due to the effect of transverse components of
the vector potential. Perhaps more significantly, we showed that the assumption that the W(z) difference
is independent of the transverse locations of x1 and x2 on the conductors is blatantly invalid at low
frequencies. This is illustrated in Fig 3.6b which shows that the conductors are not equipotentials of Az at
DC (or at low frequencies near DC). The bottom line is that we don't expect Item 2 of the theory to be
valid all the wave from high frequencies down to DC.
Item 3 also has subtle problems at low frequencies. The basic ansatz of Appendix D is that all non-
power/energy quantities relating to the inside of the wire have time and z dependence given by ej(ωt-βdz)
as shown for the E field in (D.1.1). For a lossless conductor, βd really is the (real) wavenumber of the
dielectric as its name suggests. Since Appendix D assumes a vacuum dielectric (G = 0, but see Section
D.9 (d)), lossless here refers only to the effect of conductor resistance. We know that low loss means high
σ and therefore small δ = 2/(ωμσ) , so for a given σ we associate low loss with high frequency. If we try
to incorporate small losses, we can use the loss model of Section D.11 (b) where we end up replacing βd
= ω/vd (no loss) with βd = (ω-jωc)/vd (small loss). A review of Appendix D shows no assumption being
made about βd being real, so the solutions are valid as well for βd being complex. If we blindly use this
lossy expression for βd as ω → 0, we obtain βd ≈ -j ωc/vd and then ej(ωt-βdz) gives a exponentially
decaying amplitude as z increases. It is "all decay and no wave". We would expect such a decaying
amplitude for V(z) along with q(z) = q(0) e-jβdz from (4.3.8). But the corresponding i(z) = i(0) e-jβdz
2
from (4.9.2) seems peculiar, since with G = 0 we expect to have no decay in the current along the line. At
DC the inductance and capacitance of the line have no effect and the model becomes just the conductor
resistance, as suggested by this DC version of Fig K.1
This issue is partially resolved by noting that Appendix D applies only to an infinite transmission line,
and then the above network model gives Rin = ∞ so i(0) = 0. We note that the low loss model just
mentioned makes use of the transmission line equations in its derivation, and these equations are known
to be invalid at low frequencies for the reasons given above in Item 2, so we don't really expect our loss
model to be valid near ω = 0.
Appendix D has other low frequency problems as well. For example, the charge pumping boundary
condition (D.2.23) says Jr(r=a-ε,θ) = jω n(θ). We then assume that Jr = σEr and this then becomes a
condition on the Er field: Er(r=a-ε,θ) = (jω/σ) n(θ). We then use this boundary condition with our
Helmholtz equation E field solutions to determine the constants Km and am and thus to obtain the E field
results shown in (D.2.33). However, we know that at DC (and presumably near DC), the radial Hall effect
exists as outlined in Section N.7. At DC we learn that in a round wire there is a Hall field Er = Es (r/a)
from (N.7.12), while at the same time Jr ≡ 0 from (N.7.11). This last result is consistent with the
boundary condition just quoted Jr(r=a-ε,θ) = jω n(θ) as ω→ 0, but our assumption that Jr = σ Er at low
frequency is seen to be grossly invalid. Normally one thinks of the radial Hall effect as a miniscule effect,
but at low frequencies all the transverse fields in a round conductor are miniscule so the Hall field
becomes significant. Moreover, Appendix D assumes no free charge density inside the conductor, but
there is a small free charge near ω = 0 due to this same Hall effect. There is also a Hall surface charge that
Appendix D ignores.
To summarize our Item 3 conclusions, the results (D.2.33) which we have used above to make plots
of the conductor current densities are expected to be invalid at low frequencies.
It is not obvious just how low ω can be for the fields (D.2.33) to remain valid. For sure they are not valid
in the immediate vicinity of ω = 0, so we cannot use these field expressions to study the limit ω→0, and
this will be illustrated below. We expect that the lower bound for ω will depend on the transmission line
geometry. As a ballpark guess we might consider this lower bound on ω to be the ωc parameter
mentioned above. We show in the two Examples of Section D.11 that fc = 7.7 KHz for Belden 8281
coaxial cable, whereas fc = 5.5 Hz for a typical power transmission line.
Proximity Effect at Low Frequency
To review, in various places in the above analysis, it was assumed that ω is high enough to put the
transmission line in either the strong or extreme skin effect regime of (3.7.3) which roughly means δ <
a/10. In order to base the analysis on "the capacitor problem" as we have done (the electro-quasi-static
model), we had to avoid the low frequency range which, expressed in terms of skin depth δ, is roughly
a/10 < δ < ∞. Only then could we be assured that φ = constant and Az = constant on the conductor
surfaces as declared in (3.7.4) and (3.7.20), and only then are the transmission line equations and
3
parameter evaluations of Chapter 4 valid. Our analysis of the proximity effect presented above inherits all
these assumptions (in addition to the requirement of being in the transmission line limit so λ >> a).
As described in the text section below (3.7.21), we might blindly assume that our transmission line
theory is "ballpark valid" in the low frequency range, and then the proximity effect calculation as given
above would also apply approximately. For example, if we use our program above with a = 10 and δ = 10,
which is deep into the low frequency range, the plots look like this for ξ1 = -3 :
|Jz| Distribution in left round wire for a = 10, δ = 20 and ξ1 = - 3.00
Fig 6.16
The current distribution |Jz| shown on the right is a flat disc which is almost horizontal but still has a very
slight proximity effect visible in the right view. Since ξ1 = -3 in this example, the conductors are "far
apart", and we certainly expect intuitively to see a nearly flat |Jz| distribution as we would see at DC (ω=
0, since no eddy currents).
However, if we instead use ξ1 = -1.00, the program gives a strong proximity effect even if we lower
the frequency way down to δ = 200 (and a = 10),
|Jz| Distribution in left round wire for a = 10, δ = 200 and ξ1 = - 1.00
Fig 6.17
Even at a very low frequency, the strongly peaked capacitor's n(θ) is maintained and "gets into" the |Jz|
distribution. This result is incorrect based on one's expectation that Jz is "uniform at DC", so for the last
example, our model blindly stretched to low ω gives a wrong result. We summarized in the previous
subsection why we expect the model to be wrong.
4
There is an escape hatch (already alluded to in the above network picture) which sheds some light on this
paradoxical limit as ω→ 0. In the eddy current analysis of Section P.8, the two parallel cylinders
considered there carry current I and -I. But our proximity effect described above is for a properly
terminated active transmission line, not two parallel wires that are shorted together at one end. A properly
terminated transmission line, which we equate with the infinite transmission line this document addresses,
must be terminated by Z0. If we naively apply our theory as if it were valid at very low ω, we have
Z0 ≡ V/I =
z
y =
R + jωL
G + jωC .
(4.11.16)
Appendix D (in particular, the charge pumping boundary condition (D.2.24) ) assumes a vacuum
dielectric, so conductance G = 0. Thus, in the limit ω → 0 we find that Z0 = ∞. If we drive this
transmission line with V = 10 volts at f = 0.1Hz, we find that I ≈ 0 and there is no current at all, so the fact
that Jz is asymmetric is not relevant.
The conclusion is that our entire theory is only "ballpark accurate" at low ω, and therefore we have no
trustworthy conclusions regarding the proximity effect at low frequencies. However, if we incorporate the
loss model of Appendix D.11 and go ahead and blindly assume "ballpark accuracy" of the Appendix D
results at low ω, here is a statement of our conclusions regarding Jz asymmetry:
1. For a well-conducting μ=μ0 round wire which is part of a 2-conductor transmission line carrying a
traveling wave of the form ej(ωt-βdz) through a vacuum dielectric, the E fields inside the wire are
completely determined by the relative moments ηm of the surface charge distribution n(θ) as obtained
from an electrostatic calculation based on the shape of the line cross section. From (D.2.33) the fields are:
Second summary of the E field solutions :
Rdc = 1
σπa2
β'2 = β2 - βd2
(D.2.33)
Ez(r,m) = (1/4) ηm I Rdc (aβ') fm
fm = [ Jm(x)
Jm+1(xa) -
Jm(x)
Jm-1(xa) ]
x = β'r
Er(r,m) = (j/4) ηm I Rdc (aβd) gm
gm = [ Jm+1(x)
Jm+1(xa) + Jm-1(x)
Jm-1(xa) ]
xa = β'a
Eθ(r,m) = (1/4) ηm I Rdc (aβd) hm
hm = [ Jm+1(x)
Jm+1(xa) - Jm-1(x)
Jm-1(xa) ]
Parameters in the E field expressions are:
a
radius of the wire
σ
conductivity of the round wire
Rdc
= 1/(πa2σ) = DC resistance of the round wire per unit length
I
current magnitude in the wire
βd
wavenumber of the dielectric wave
β
wavenumber inside the conductor
β'
β'2 = β2 - βd2
5
ηm
relative moments of n(θ) , ηm = Nm/N0 as in (D.1.5)
where ( see App D.11 for the soft cutoff frequency ωc) ,
βd = (ω-jωc)/vd
ωc = (vd2/2) (R'dcC)
vd = c = the speed of light
ω = angular frequency of the monochromatic wave
R'dc = total resistance per unit length of both conductors.
C = capacitance per unit length of the two conductors
β = ej3π/4 ( 2 /δ) = (j-1)/δ
δ ≡ 2/ωμ0σ = skin depth
(6.5.21)
2. At all frequencies, including the limit ω→0 (where Z0 → ∞), the current distribution Jz in the wire is
non-uniform, and is determined from Jz = σEz. The current is non-uniform because the amplitudes of the
partial-wave fields Ez(r,m) for m≠0 do not in general vanish -- see for example (D.11.17,18). The one
exception occurs if the round wire is the center conductor of a coaxial cable (see Chapter 2). See
Appendix D.10 and D.11 for discussion of the high and low frequency limits of the boxed E fields above.
3. These conclusions apply to an infinite transmission line, or to a truncated transmission line which is
properly terminated by Zt= Z0 where Z0 is given by (4.4.12) with G = 0 (since vacuum dielectric). The
conclusions do not apply to a truncated transmission line which is terminated with some fixed impedance
at all ω, such as Zt = 0.
We know that for the problem of two parallel cylindrical conductors (or any uniform parallel conductors)
which carry I and -I and are shorted at one end, Jz is uniform at DC. We know this because at ω= 0 there
are no eddy currents induced by one wire into the other. The DC B field of wire #2 has no influence on
the current density Jz in wire #1, though it does induce a tiny Hall charge onto the surface of wire #1 and
a corresponding transverse Hall E field since the B field of wire #2 temporarily deflects electrons in wire
#1 (see Appendix N for various Hall examples). This deflection effect is mentioned in the text below Fig
P.12 in Appendix P. In any event, if the DC B field of wire #2 does not affect Jz in wire #1, then Jz in
wire #1 doesn't even know that wire #2 is present, so wire #2 could just as well be removed. The isolated
wire #1 then if round (Chapter 2) would have a uniform Jz certainly with no proximity effect.
It would be reassuring if our transmission line model could account for the gradual transition from low ω
to ω = 0 where the asymmetric Jz smoothly approaches a uniform a Jz. Unfortunately, our model only
applies to an infinite (or properly terminated) transmission line, and thus cannot expose the ω→0 limit for
parallel conductors terminated in a fixed load. One can superpose a left- and right-going Appendix D
wave solution to get a standing wave situation to model the shorted cylinder pair, but since the Appendix
D solutions are themselves not valid at low ω, this does not resolve the problem.
In a proper treatment of the fixed-load problem, as ω→0 one would see the eddy currents gradually
decrease, one would arrive at a DC current I, and one would have Jz → uniform. The problem with our
transmission line model is that, for the infinite line, or one in which the termination is constantly
increased to equal Z0, as ω→0 the eddy currents do gradually vanish, but so does the Jz associated with
the current I, so the ratio of these currents maintains the asymmetric pattern of Fig 6.17.
6
A solution of the fixed load two-cylinder problem could be based on the eddy current methods outlined
qualitatively in Appendix P and is no doubt available somewhere in the literature. This solution would
then show the proximity and skin effects gradually vanishing as ω→ 0, leaving a uniform Jz.